U3Ryb25nIFBvaW50cw==

  • UmVsaWFiaWxpdHkgYW5kIHBlcmZvcm1hbmNl

  • U2FmZXR5IG9mIHByb3BlcnR5IGFuZCBwZXJzb25uZWw=

  • U2ltcGxpY2l0eQ==

  • RWFzeSB0byBpbnN0YWxs

RnVuY3Rpb24=

U0lSQ08gYXJlIG1hbnVhbGx5IG9yIHJlbW90ZWx5IG9wZXJhdGVkIG11bHRpcG9sYXIgbG9hZCBicmVhayBzd2l0Y2hlcy48YnIgLz4NClRoZXkgbWFrZSBhbmQgYnJlYWsgdW5kZXIgbG9hZCBjb25kaXRpb25zIGFuZCBwcm92aWRlIHNhZmUgaXNvbGF0aW9uLjxiciAvPg0KU0lSQ0/CoGFyZSBkZXNpZ25lZCBmb3IgNDE1IFZBQyBhbmQgREMgbG93IHZvbHRhZ2UgZWxlY3RyaWNhbCBjaXJjdWl0cy4=

Classification

UNSPSC 39122233
ETIM Class EC000216
IGCC 5290

Commerce

Description Manually operated Load break switch SIRCO frame B5ds with 8 poles, 400A, 415VAC/500VDC frontal direct operation with handle type J1 or frontal external operation with handle type S4. Delivered without handle
Effective date 1999-01-01
Offer Life Cycle Code 40
Country of origin FR

Environmental Sustainability

PEP Filename SOCO-00070-V01.02-EN.pdf
Climate change - Total - Cradle to Grave [kg CO₂ eq.] 726
Climate change - Total - Cradle to Gate [kg CO₂ eq.] 98

ETIM - Electrical characteristics

Max. rated operation voltage Ue AC [V] 500
Rated operating voltage [V] 400..500
Rated permanent current Iu [A] 400
Rated permanent current at AC-23, 400 V [A] 400
Rated permanent current at AC-21, 400 V [A] 400
Rated short-time withstand current lcw [kA] 13
Rated operation power at AC-23, 400 V [kW] 220
Switching power at 400 V [kW] 220
Conditioned rated short-circuit current Iq [kA] 100
Number of poles 8

ETIM - Mechanical characteristics

Suitable for floor mounting No
Suitable for front mounting 4-hole No
Suitable for front mounting centre No
Suitable for distribution board installation No
Suitable for intermediate mounting Yes
Colour control element Other
Degree of protection (IP), front side IP20

ETIM - Technical features

Version as main switch Yes
Version as maintenance-/service switch Yes
Version as safety switch Yes
Version as emergency stop installation Yes
Version as reversing switch No
Number of switches 1
Motor drive optional No
Motor drive integrated No
Voltage release optional No
Device construction Built-in device fixed built-in technique
Type of control element Other
Interlockable Yes
Type of electrical connection of main circuit Bolt connection

Logistics

GTIN/EAN 3596031119523
Customs number 8536508000
Price unit PC
Weight of the packing unit [kg] 12.03
Length of the packing unit [m] 0.47
Width of the packing unit [m] 0.305
Depth of the packing unit [m] 0.36

Norms

Conformity to standards IEC

Technical Characteristics

Control operator Direct : C1 / External : S4
Number of poles 8
Rated voltage 415 VAC / 500 VDC
Rated current [A] 400
Type Front Operation
Frame size B5ds

Documentation

  • PDF
    SIRCO - Interrupteurs-sectionneurs pour la distribution d'énergie
    Select
  • PDF
    Interrupteurs-sectionneurs
    Select
  • PDF
    Load break switches
    Select
  • PDF
    SIRCO - Load break switches for power distribution
    Select
  • PDF
    SIRCO 400-630A_CCC certificate
    Select
  • PDF
    SIRCO 6&8P 125A to 3200A_PEP
    Select
  • SIRCO 8X400A F 90° CAD 26018040

References

SIRCO is available in 89 versions

Item Type Rated current [A] Number of poles Frame size Control operator Rated voltage Select
26003014 Front Operation 125 3 B3 Direct : B1,J1 / External : S2 415 VAC / 500 VDC
26004014 Front Operation 125 4 B3 Direct : B1,J1 / External : S2 415 VAC / 500 VDC
26016013 Front Operation 125 6 B3ds Direct : B3 / External : S2 415 VAC / 500 VDC
26018013 Front Operation 125 8 B3ds Direct : B3 / External : S2 415 VAC / 500 VDC
26003017 Front Operation 160 3 B3 Direct : B1,J1 / External : S2 415 VAC / 500 VDC
26004017 Front Operation 160 4 B3 Direct : B1,J1 / External : S2 415 VAC / 500 VDC
26016016 Front Operation 160 6 B3ds Direct : B3 / External : S2 415 VAC / 500 VDC
26018016 Front Operation 160 8 B3ds Direct : B3 / External : S2 415 VAC / 500 VDC
26003019 Front Operation 200 3 B3 Direct : B1,J1 / External : S2 415 VAC / 500 VDC
26003021 Front Operation 200 3 B4 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26004019 Front Operation 200 4 B3 Direct : B1,J1 / External : S2 415 VAC / 500 VDC
26004021 Front Operation 200 4 B4a Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26003026 Front Operation 250 3 B4 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26004026 Front Operation 250 4 B4 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26016025 Front Operation 250 6 B4ds Direct : C1 / External : S4 415 VAC / 500 VDC
26018025 Front Operation 250 8 B4ds Direct : C1 / External : S4 415 VAC / 500 VDC
26003030 Front Operation 315 3 B4 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26003032 Front Operation 315 3 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26004030 Front Operation 315 4 B4 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26004032 Front Operation 315 4 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26003039 Front Operation 400 3 B4 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26003041 Front Operation 400 3 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26004039 Front Operation 400 4 B4 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26004041 Front Operation 400 4 B5a Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26016040 Front Operation 400 6 B5ds Direct : C1 / External : S4 415 VAC / 500 VDC
26003049 Front Operation 500 3 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26003051 Front Operation 500 3 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26004049 Front Operation 500 4 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26004051 Front Operation 500 4 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26003064 Front Operation 630 3 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26004064 Front Operation 630 4 B5b Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26016063 Front Operation 630 6 B5ds Direct : C1 / External : S4 415 VAC / 500 VDC
26018063 Front Operation 630 8 B5ds Direct : C1 / External : S4 415 VAC / 500 VDC
26003079 Front Operation 800 3 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26003081 Front Operation 800 3 B6 Direct : C2 / External : S4 415 VAC / 500 VDC
26004079 Front Operation 800 4 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26004081 Front Operation 800 4 B6 Direct : C2 / External : S4 415 VAC / 500 VDC
26016080 Front Operation 800 6 B6 Direct : C2 / External : S4 415 VAC / 500 VDC
26018080 Front Operation 800 8 B6ds Direct : C2 / External : V0 415 VAC / 500 VDC
26003099 Front Operation 1000 3 B6 Direct : C2 / External : S4 415 VAC / 500 VDC
26004099 Front Operation 1000 4 B6 Direct : C2 / External : S4 415 VAC / 500 VDC
26016100 Front Operation 1000 6 B6 Direct : C2 / External : S4 415 VAC / 500 VDC
26018100 Front Operation 1000 8 B6ds Direct : C2 / External : V0 415 VAC / 500 VDC
26003119 Front Operation 1250 3 B6 Direct : C2 / External : S4 415 VAC / 500 VDC
26003121 Front Operation 1250 3 B7 Direct : C2 / External : S4 415 VAC / 500 VDC
26004119 Front Operation 1250 4 B6 Direct : C2 / External : S4 415 VAC / 500 VDC
26004120 Front Operation 1250 4 B7 Direct : C2 / External : S4 415 VAC / 500 VDC
26004121 Front Operation 1250 4 B7 Direct : C2 / External : S4 415 VAC / 500 VDC
26016120 Front Operation 1250 6 B7ds Direct : C2 / External : V0 415 VAC / 500 VDC
26018120 Front Operation 1250 8 B7ds Direct : C2 / External : V0 415 VAC / 500 VDC
26003161 Front Operation 1600 3 B7 Direct : C2 / External : S4 415 VAC / 500 VDC
26004161 Front Operation 1600 4 B7 Direct : C2 / External : S4 415 VAC / 500 VDC
26016160 Front Operation 1600 6 B7ds Direct : C2 / External : V0 415 VAC / 500 VDC
26018160 Front Operation 1600 8 B7ds Direct : C2 / External : V0 415 VAC / 500 VDC
26003181 Front Operation 1800 3 B8 Direct : S5 / External : S5 415 VAC / 500 VDC
26004181 Front Operation 1800 4 B8 Direct : S5 / External : S5 415 VAC / 500 VDC
26003200 Front Operation 2000 3 B8 Direct : S5 / External : V2 415 VAC / 500 VDC
26004200 Front Operation 2000 4 B8 Direct : S5 / External : V2 415 VAC / 500 VDC
26018250 Front Operation 2500 8 B8ds Direct : S5 / External : V2 415 VAC / 500 VDC
26003250 Front Operation 2500 3 B8 Direct : S5 / External : V2 415 VAC / 500 VDC
26004250 Front Operation 2500 4 B8 Direct : S5 / External : V2 415 VAC / 500 VDC
26003320 Front Operation 3200 3 B8 Direct : S5 / External : V2 415 VAC / 500 VDC
26004320 Front Operation 3200 4 B8 Direct : S5 / External : V2 415 VAC / 500 VDC
26053013 Side Operation 125 3 B3 Direct : B1,J1 / External : S2 415 VAC / 500 VDC
26003401 Front Operation 4000 3 B9 Direct : V0 / External : V0 415 VAC / 500 VDC
26004401 Front Operation 4000 4 B9 Direct : V0 / External : V0 415 VAC / 500 VDC
26003500 Front Operation 5000 3 B9 Direct : V0 / External : V0 415 VAC / 500 VDC
26004500 Front Operation 5000 4 B9 Direct : V0 / External : V0 415 VAC / 500 VDC
26054013 Side Operation 125 4 B3 Direct : B1,J1 / External : S2 415 VAC / 500 VDC
26053017 Side Operation 160 3 B3 Direct : B1,J1 / External : S2 415 VAC / 500 VDC
26054017 Side Operation 160 4 B3 Direct : B1,J1 / External : S2 415 VAC / 500 VDC
26053021 Side Operation 200 3 B4 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26053051 Side Operation 500 3 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26054021 Side Operation 200 4 B4 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26053026 Side Operation 250 3 B4 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26054064 Side Operation 630 4 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26054026 Side Operation 250 4 B4 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26053032 Side Operation 315 3 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26054032 Side Operation 315 4 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26053040 Side Operation 400 3 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26053041 Side Operation 400 3 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26054040 Side Operation 400 4 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26054041 Side Operation 400 4 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26054051 Side Operation 500 4 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26053064 Side Operation 630 3 B5 Direct : B2, J1 / External : S2 415 VAC / 500 VDC
26053119 Side Operation 1250 3 B6 Direct : C2 / External : S4 415 VAC / 500 VDC
26054119 Side Operation 1250 4 B6 Direct : C2 / External : S4 415 VAC / 500 VDC
26053181 Side Operation 1800 3 B8 Direct : S5 / External : S5 415 VAC / 500 VDC
26054181 Side Operation 1800 4 B8 Direct : S5 / External : S5 415 VAC / 500 VDC